CBC Test Specification
  • LTE
  • 5G
  • Abbreviations
  • CBS intro
  • Standards
  • Identifiers
GitHub
  • LTE
  • 5G
  • Abbreviations
  • CBS intro
  • Standards
  • Identifiers
GitHub
  • << Back to List of TCs
  • UPDATE-2

  • Description
  • Pre-requisites
  • Steps to execute
  • Information flow
  • Result
  • Iterations

UPDATE-2 Update message of ongoing warning in additional language. No indication.

Description

Update the message content of an ongoing cell broadcast in a language different to the local one. the alert area is not modified and indication is not requested from the network.

Pre-requisites

  • Activate a cell broadcast message in a language different to the local one in a specific area (e.g. following the procedure in TC START-2). For simplicitly, this TC is assumes that the area is fully covered by eNBs controlled by the same MME.
  • Alert timing defined so that the broadcast will run for suficient time to execute this test completely.
  • Configure the different systems to not request SBc-AP indication messages.

Steps to execute

  1. CBE sends CAP Alert message with:
    • msgType sub-element set to "Update".
    • references sub-element contains the identifier of the CAP Alert message that triggered the current active broadcast.
    • A single info element with the updated message in a language different to the local one. The message shall be at least 2 pages long but not more than 4 pages.
    • Time information that allows the CBC to calculate the repetition period and the number of repetitions.
    • Alert area shall be the same as that in the CAP Alert message (flow 1) that triggered the broadcast message being updated.

Information flow

tc_lte_update_2

Result

A CBC has two different ways to process this update request from the CBE. The result depends on the option implemented.

Option 1 - CBC uses WRWReq

Verify that:

  1. The CBC sends a WRITE-REPLACE WARNING REQUEST (flow 5.a) to the MME that controls the eNBs that cover the alert area. Presence of parameters in this message shall be as shown in the following table:

    Information ElementIncludedValue
    Message IdentifierYesfor current iteration
    Serial NumberYesSame values of GS and Message code as in flow 2 but different update number
    List of TAIsShouldSame as flow 2
    Warning Area ListYesSame as flow 2
    Repetition PeriodYesAccording to the timing requested in flow 4
    Extended Repetition PeriodNo
    Number of Broadcast RequestedYesAccording to the timing requested in flow 4
    Warning TypeNo
    Warning Security InformationNo
    Data Coding SchemeYesSet for additional language according to 3GPP TS 23.038
    Warning Message ContentsYesAlert message encoded according to the value of DCS above
    Concurrent Warning Message IndicatorYestrue
    Send Write-Replace-Warning-IndicationNo
    Global eNB IDNo
  2. The MME responds with a WRITE-REPLACE WARNING RESPONSE (flow 6.a) with contents according to the following table.

    Information ElementIncludedValue
    Message IdentifierYesSame as in flow 5.a
    Serial NumberYesSame as in flow 5.a
    CauseYesSet to value Message accepted
    Criticality DiagnosticsNo
    Unknown Tracking Area ListNo
  3. Handsets in the alert area receive the updated alert and display it correctly, regardless of whether they were in the area and displayed the first version of this message or entered the area once the message was updated.

Option 2 - CBC Stops the initial message and sends the updated as a new message

Verify that:

  1. The CBC sends a STOP WARNING REQUEST (flow 5.b) to the MME that controls the eNBs that cover the alert area. Presence of parameters in this message shall be as shown in the following table:

    Information ElementIncludedValue
    Message IdentifierYesfor current iteration
    Serial NumberYesSame as in flow 2
    List of TAIsMaySame as in flow 2
    Warning Area ListMaySame as in flow 2
    Send Stop Warning IndicationNo
    Stop All IndicationNo
  2. The MME responds with a STOP WARNING RESPONSE (flow 6.b) with contents according to the following table.

    Information ElementIncludedValue
    Message IdentifierYesSame as in flow 2
    Serial NumberYesSame as in flow 2
    CauseYesSet to value Message accepted
    Criticality DiagnosticsNo
    Unknown Tracking Area ListNo
  3. Broadcast of the alert has stopped in all the cells in which it was active.

  4. The CBC sends a WRITE-REPLACE WARNING REQUEST (flow 7.b) to the MME that controls the eNBs that cover the alert area. Presence of parameters in this message shall be as shown in the following table:

    Information ElementIncludedValue
    Message IdentifierYesfor current iteration
    Serial NumberYesDifferent to the one in flow 2
    List of TAIsShouldSame as flow 2
    Warning Area ListYesSame as flow 2
    Repetition PeriodYesAccording to the timing requested in flow 4
    Extended Repetition PeriodNo
    Number of Broadcast RequestedYesAccording to the timing requested in flow 4
    Warning TypeNo
    Warning Security InformationNo
    Data Coding SchemeYesSet for additional language according to 3GPP TS 23.038
    Warning Message ContentsYesAlert message encoded according to the value of DCS above
    Concurrent Warning Message IndicatorYestrue
    Send Write-Replace-Warning-IndicationNo
    Global eNB IDNo
  5. The MME responds with a WRITE-REPLACE WARNING RESPONSE (flow 8.b) with contents according to the following table.

    Information ElementIncludedValue
    Message IdentifierYesSame as in flow 7.b
    Serial NumberYesSame as in flow 7.b
    CauseYesSet to value Message accepted
    Criticality DiagnosticsNo
    Unknown Tracking Area ListNo
  6. Handsets in the alert area receive the updated alert and display it correctly, regardless of whether they were in the area and displayed the first version of this message or entered the area once the message was updated.

Iterations

This TC should be iterated for the alert types in the following table that are applicable in the country in which the CBC is deployed:

IterationAlert TypeMessage identifier
1EU-Alert Level 1 \ WEA Presidential4383 (0x111F)
2EU-Alert Level 2 \ WEA Extreme[4384, 4385] ([0x1120, 0x1121])
3EU-Alert Level 3 \ WEA Severe[4386 ... 4391] ([0x1122 ... 0x1127)
4EU-Alert & WEA AMBER4392 (0x1128)
5WEA RMT4393 (0x1129)
6WEA Exercise4394 (0x112A)
7WEA Operator defined use4395 (0x112B)
8EU-Alert Level 4 \ WEA Public Safety4397 (0x112D)
9WEA State/Local test4399 (0x112F)
Contributors: Raquel Marina Noguera Oishi