CBC Test Specification
  • LTE
  • 5G
  • Abbreviations
  • CBS intro
  • Standards
  • Identifiers
GitHub
  • LTE
  • 5G
  • Abbreviations
  • CBS intro
  • Standards
  • Identifiers
GitHub
  • << Back to List of TCs
  • STOP-9

  • Description
  • Pre-requisites
  • Steps to execute
  • Information flow
  • Result
  • Iterations

STOP-9 Partial stop of an active alert.

Description

Stop ongoing alert in some of the cells in which it is active and continue active in all other cells.

Pre-requisites

  • An alert is ongoing within an area covered by a multiple cells.

Steps to execute

  1. CBE sends CAP Cancel message with:
    • The same identifier as in the CAP Alert message that started the broadcast.
    • An area that is a subset of the area of the current active alert.

Information flow

tc1_lte_stop_9

Result

Verify that:

  1. The CBC sends a STOP WARNING REQUEST only to the MMEs that control the eNBs that shall stop broadcasting the ongoing alert. Presence of parameters in this message shall be as shown in the following table:

    Information ElementIncludedValue
    Message IdentifierYesfor current iteration
    Serial NumberYesSame as for ongoing broadcast
    List of TAIsMayTAIs of all the cells in IE Warning Area List
    Warning Area ListMayList of cells in which the alert shall stop
    Send Stop Warning IndicationYestrue
    Stop All IndicationNo
  2. The MME responds with a STOP WARNING RESPONSE with contents according to the following table.

    Information ElementIncludedValue
    Message IdentifierYesSame as in flow 2
    Serial NumberYesSame as in flow 2
    CauseYesSet to value Message accepted
    Criticality DiagnosticsNo
    Unknown Tracking Area ListNo
  3. The MME sends one or more STOP WARNING INDICATION messages with content according to the following table.

    Information ElementIncludedValue
    Message IdentifierYesSame as in flow 2
    Serial NumberYesSame as in flow 2
    Broadcast Cancelled Area ListYesA list with cells listed in Warning Area List IE in flow 2
    Broadcast Empty Area ListNo

The union of all the ECGIs in all the *Broadcast Cancelled Area List" IEs received shall contain all the ECGIs inside the Warning Area List of flow 2.

  1. Broadcast of the alert has stopped in all the cells inside the Warning Area List of flow 2, but continues active in all other cells in which it was active.

  2. If supported by the CBE - CBC interface, the CBC informs the CBE about the successful outcome of the partial stop.

Iterations

This TC should be iterated for the alert types in the following table that are applicable in the country in which the CBC is deployed:

IterationAlert TypeMessage identifier
1EU-Alert Level 1 \ WEA Presidential4370 (0x1112)
2EU-Alert Level 2 \ WEA Extreme[4371, 4372] ([0x1113, 0x1114])
3EU-Alert Level 3 \ WEA Severe[4373 ... 4378] ([0x1115 ... 0x111A)
4EU-Alert & WEA AMBER4379 (0x111B)
5WEA RMT4380 (0x111C)
6WEA Exercise4381 (0x111D)
7WEA Operator defined use4382 (0x111E)
8EU-Alert Level 4 \ WEA Public Safety4396 (0x112C)
9WEA State/Local test4398 (0x112E)
10EU-Info6400 (0x1900)
Contributors: Raquel Marina Noguera Oishi