STOP-6 Completely stop, without indication, a continuous alert in additional language.
Description
Stop ongoing time-unlimited cell broadcast of an alert in a language different to the local one. The alert area is covered by cells within a single TA.
Pre-requisites
- Define an alert area within the coverage of a single TA.
- There is no ongoing cell broadcast in any of the cells that cover the alert area.
- The message is in language different to the local language.
- The Alert request indicates that this alert shall run indefinitely.
Steps to execute
- CBE sends CAP Alert message with:
- A single info element. I.e. only one message in one language.
- alertinfo.language.code set to the value of the additional language (e.g. sl-SI for Slovenian).
- alertinfo.instruction.text content of the alert message in the language indicated by the code above.
- alertInfo.expires is not present. This indicates that the alert shall run indefinitely.
- Alert area that is inside the area controlled by a single MME. I.e. only one MME is involved in this test.
- Let the alert run for at least two repetition periods.
- The CBE sends CAP Cancel message with:
- The same identifier as in the CAP Alert message that started the broadcast.
- All other mandatory parameters.
- If the info element is present, then its content must match the ongoing alert.
Information flow
Result
Verify that:
The CBC sends a STOP WARNING REQUEST only to the one MME that controls the eNBs that control the cells where the ongoing alert is broadcasted. Presence of parameters in this message shall be as shown in the following table:
Information Element Included Value Message Identifier Yes for current iteration Serial Number Yes Same as for ongoing broadcast List of TAIs May TAI of the cells in IE Warning Area List Warning Area List May List of cells that cover the alert area Send Stop Warning Indication Yes true Stop All Indication No The MME responds with a STOP WARNING RESPONSE with contents according to the following table.
Information Element Included Value Message Identifier Yes Same as in flow 2 Serial Number Yes Same as in flow 2 Cause Yes Set to value Message accepted Criticality Diagnostics No Unknown Tracking Area List No Broadcast of the alert has stopped in all the cells in which it was active.
Iterations
This TC should be iterated for the alert types in the following table that are applicable in the country in which the CBC is deployed:
| Iteration | Alert Type | Message identifier |
|---|---|---|
| 1 | EU-Alert Level 1 \ WEA Presidential | 4383 (0x111F) |
| 2 | EU-Alert Level 2 \ WEA Extreme | [4384, 4385] ([0x1120, 0x1121]) |
| 3 | EU-Alert Level 3 \ WEA Severe | [4386 ... 4391] ([0x1122 ... 0x1127) |
| 4 | EU-Alert & WEA AMBER | 4392 (0x1128) |
| 5 | WEA RMT | 4393 (0x1129) |
| 6 | WEA Exercise | 4394 (0x112A) |
| 7 | WEA Operator defined use | 4395 (0x112B) |
| 8 | EU-Alert Level 4 \ WEA Public Safety | 4397 (0x112D) |
| 9 | WEA State/Local test | 4399 (0x112F) |