STOP-1 Completely stop, without indication, a time-limited alert in local language.

Description

Stop ongoing cell broadcast of an alert in local language in an area covered by cells within a single TA.

Pre-requisites

  • An alert in local language is ongoing within an area covered by a single TA.

Steps to execute

  1. CBE sends CAP Cancel message with:
    • The same identifier as in the CAP Alert message that started the broadcast.

The CAP Cancel message shall contain all other mandatory paramters, but it does no need to contain info elements.

Information flow

tc1_lte_stop_1

Result

Verify that:

  1. The CBC sends a STOP WARNING REQUEST only to the one MME that controls the eNBs that control the cells where the ongoing alert is broadcasted. Presence of parameters in this message shall be as shown in the following table:

    Information ElementIncludedValue
    Message IdentifierYesfor current iteration
    Serial NumberYesSame as for ongoing broadcast
    List of TAIsMayTAI of the cells in IE Warning Area List
    Warning Area ListMayList of cells that cover the alert area
    Send Stop Warning IndicationNo
    Stop All IndicationNo
  2. The MME responds with a STOP WARNING RESPONSE with contents according to the following table.

    Information ElementIncludedValue
    Message IdentifierYesSame as in flow 2
    Serial NumberYesSame as in flow 2
    CauseYesSet to value Message accepted
    Criticality DiagnosticsNo
    Unknown Tracking Area ListNo
  3. Broadcast of the alert has stopped in all the cells in which it was active.

Iterations

This TC should be iterated for the alert types and message lengths in the following table that are applicable in the country in which the CBC is deployed:

IterationAlert TypeMessage identifierText length
1EU-Alert Level 1 \ WEA Presidential4370 (0x1112)Short
2EU-Alert Level 2 \ WEA Extreme[4371, 4372] ([0x1113, 0x1114])Short
3EU-Alert Level 3 \ WEA Severe[4373 ... 4378] ([0x1115 ... 0x111A)Short
4EU-Alert & WEA AMBER4379 (0x111B)Short
5WEA RMT4380 (0x111C)Short
6WEA Exercise4381 (0x111D)Short
7WEA Operator defined use4382 (0x111E)Short
8EU-Alert Level 4 \ WEA Public Safety4396 (0x112C)Short
9WEA State/Local test4398 (0x112E)Short
10EU-Info6400 (0x1900)Short
11EU-Alert Level 1 \ WEA Presidential4370 (0x1112)Long
12EU-Alert Level 2 \ WEA Extreme[4371, 4372] ([0x1113, 0x1114])Long
13EU-Alert Level 3 \ WEA Severe[4373 ... 4378] ([0x1115 ... 0x111A)Long
14EU-Alert & WEA AMBER4379 (0x111B)Long
15WEA RMT4380 (0x111C)Long
16WEA Exercise4381 (0x111D)Long
17WEA Operator defined use4382 (0x111E)Long
18EU-Alert Level 4 \ WEA Public Safety4396 (0x112C)Long
19WEA State/Local test4398 (0x112E)Long
20EU-Info6400 (0x1900)Long
21EU-Alert Level 1 \ WEA Presidential4370 (0x1112)Very long
22EU-Alert Level 2 \ WEA Extreme[4371, 4372] ([0x1113, 0x1114])Very long
23EU-Alert Level 3 \ WEA Severe[4373 ... 4378] ([0x1115 ... 0x111A)Very long
24EU-Alert & WEA AMBER4379 (0x111B)Very long
25EU-Alert Level 4 \ WEA Public Safety4396 (0x112C)Very long
26EU-Info6400 (0x1900)Very long

A short message fits into one page. A long requires 4 pages and a very long one 15 pages.

Text Encoding

How many characters fit into one page depends on whether the message is encoded using GSM7 (1 char = 7 bits, 1 shifted char = 14 bits) or UCS2 (1 char = 16 bits).

Select appropriate short / long / very long messages according to the encoding used for the local and additional languages that you are testing.

WEA sets the limit to 4 pages. So we do not need to test very long messages for WEA only types. If you are testing EU-Alert and your country sets a limit for the length of messages, you should test the long or very long cases using this limit.