CBC Test Specification
  • LTE
  • 5G
  • Abbreviations
  • CBS intro
  • Standards
  • Identifiers
GitHub
  • LTE
  • 5G
  • Abbreviations
  • CBS intro
  • Standards
  • Identifiers
GitHub
  • << Back to List of TCs
  • START-7

  • Description
  • Pre-requisites
  • Steps to execute
  • Information flow
  • Result
  • Iterations

START-7 Global Alert in Additional language. With indication.

Description

Cell broadcast of an alert in a language different to the local one.
The alert area extends the whole coverage area of the MNO.
The MMEs are requested to report updates for the alert.

Pre-requisites

  • If indication is not requested via the CBE - CBC interface, then configure the CBC to request indications from the MMEs.
  • The alert area extends the whole coverage area of the network.
  • There is no ongoing cell broadcast in the network.
  • The message is in a language different to the local one.
  • Alert timing defined so it is easy to verify that the value of the parameters Number of broadcast and broadcast period that the CBC sends to the MMEs.

Steps to execute

  1. CBE sends CAP Alert message with:
    • A single info element. I.e. only one message in one language.
    • alertinfo.language.code set to the value of a language other than the local one (e.g. sl-SI for Slovenian).
    • alertinfo.instruction.text content of the alert message in the language of the code above. The message of this message should be such that it needs four pages when encoded.
    • Time information that allows the CBC to calculate the repetition period and the number of repetitions.
    • Alert area is either no defined or defined to cover the whole region covered by the whole LTE network under test.
    • If indication is requested via the CBE - CBC interface, then include the parameters for requesting indication.

Information flow

tc_lte_start_7

Result

Verify that:

  1. The CBC sends one WRITE-REPLACE WARNING REQUEST to each of the MMEs to which it is connected. Presence of parameters in this message shall be as shown in the following table:

    Information ElementIncludedValue
    Message IdentifierYesfor current iteration
    Serial NumberYes
    List of TAIsNo
    Warning Area ListNo
    Repetition PeriodYesAccording to the timing requested in flow 1.
    Extended Repetition PeriodNo
    Number of Broadcast RequestedYesAccording to the timing requested in flow 1.
    Warning TypeNo
    Warning Security InformationNo
    Data Coding SchemeYesSet for the language selected according to 3GPP TS 23.038
    Warning Message ContentsYesAlert message encoded according to the value of DCS above
    Concurrent Warning Message IndicatorYestrue
    Send Write-Replace-Warning-IndicationYestrue
    Global eNB IDNo
  2. Each MME responds with a WRITE-REPLACE WARNING RESPONSE message with content according to the following table.

    Information ElementIncludedValue
    Message IdentifierYesSame as in flow 2
    Serial NumberYesSame as in flow 2
    CauseYesSet to value Message accepted
    Criticality DiagnosticsNo
    Unknown Tracking Area ListNo
  3. Each MME sends one or more WRITE-REPLACE WARNING INDICATION messages with content according to the following table.

    Information ElementIncludedValue
    Message IdentifierYesSame as in flow 2
    Serial NumberYesSame as in flow 2
    Broadcast Scheduled Area ListYesList of cells for which broadcast is active
    Broadcast Empty Area ListMayList of cells for which broadcast failed
  4. Broadcast is active in all the eNBs.

  5. Report outcome to the CBE, if the CBE-CBC interface supports it.

  6. Handsets in the alert area receive and display it correctly.

Iterations

This TC should be executed for the alert types in the following table that are applicable in the country in which the CBC is deployed:

IterationAlert TypeMessage identifier
1EU-Alert Level 1 \ WEA Presidential4383 (0x111F)
2EU-Alert Level 2 \ WEA Extreme[4384, 4385] ([0x1120, 0x1121])
3EU-Alert Level 3 \ WEA Severe[4386 ... 4391] ([0x1122 ... 0x1127)
4EU-Alert & WEA AMBER4392 (0x1128)
5WEA RMT4393 (0x1129)
6WEA Exercise4394 (0x112A)
7WEA Operator defined use4395 (0x112B)
8EU-Alert Level 4 \ WEA Public Safety4397 (0x112D)
9WEA State/Local test4399 (0x112F)
Contributors: Raquel Marina Noguera Oishi